Every piece that leaves our plant is fabricated to code and verified with our own inspection and testing before it ships.
Fabrication standards
- AWS D1.1Structural Welding Code – Steel.
- AWS D1.5Bridge Welding Code, for bridges and bridge girders.
- NCh 428Chilean standard for the execution of steel construction.
Quality
Quality Department
Our own team of inspectors controls fabrication from start to finish and delivers the quality records for every project.
Dimensional inspection
- Dimensions and tolerances check
- Verification against shop drawings
- Release of pieces before coating and shipping
Non-destructive testing (NDT)
- Visual testing (VT)
- Penetrant testing (PT)
- Magnetic particle testing (MT)
- Ultrasonic testing (UT)
- Level III inspector per ASNT SNT-TC-1A in all four methods
- Radiographic testing (RT) by a specialized subcontractor
Coating tests
- Dry film thickness (DFT) measurement
- Dolly pull-off adhesion testing
- Holiday testing (discontinuity detection)